2,105 research outputs found

    Probabilistic Settlement Analysis of Granular Soft Soil Foundation in Southern China Considering Spatial Variability

    Get PDF
    In this chapter, the method of combining the theory of random field and numerical analysis was used to systematically analyze the settlement probability of the soft soil foundation in the south of China, considering the effect of spatial variability of soil parameters. Based on the midpoint discretization and Cholesky decomposition, the cross-correlated non-Gaussian random field of cohesion and internal friction angle was constructed, which had considered the cross-correlation, and a single parameter random field of modulus was also constructed. The Monte-Carlo stochastic finite element program for two-dimensional foundation probabilistic settlement was developed in APDL language. The influence of spatial variability of soil parameters on probability foundation settlement was studied. The results indicate that the foundation settlement increases with the increase of coefficient variation and correlation distance. Modulus is the most important parameter for foundation settlement. The settlement of foundation is more sensitive to the correlation distance in vertical direction. Based on exponential square autocorrelation function, the continuity of random fields is obviously better, and the foundation settlement is larger. On the contrary, the fluctuation of random fields is larger, and the foundation settlement is smaller with single exponential autocorrelation function

    Noncontact Three-Dimensional Diffuse Optical Imaging of Deep Tissue Blood Flow Distribution

    Get PDF
    The present invention provides for three-dimensional reflectance diffuse optical imaging of deep tissue blood flow distribution that removes the need for probe-tissue contact, thereby allowing for such technology to be applied to sensitive, vulnerable, damaged, or reconstructive tissue. The systems utilize noncontact application and detection of near-infrared light through optical lens and detection through a linear array or two-dimensional array of avalanche photodiodes or a two-dimensional array of detectors provided by charge-coupled-device (CCD). Both further feature a finite-element-method (FEM) based facilitation to provide for three-dimensional flow image reconstruction in deep tissues with arbitrary geometries

    Noncontact Diffuse Correlation Tomography of Human Breast Tumor

    Get PDF
    Our first step to adapt our recently developed noncontact diffuse correlation tomography (ncDCT) system for three-dimensional (3-D) imaging of blood flow distribution in human breast tumors is reported. A commercial 3-D camera was used to obtain breast surface geometry, which was then converted to a solid volume mesh. An ncDCT probe scanned over a region of interest on the mesh surface and the measured boundary data were combined with a finite element framework for 3-D image reconstruction of blood flow distribution. This technique was tested in computer simulations and in vivo human breasts with low-grade carcinoma. Results from computer simulations suggest that relatively high accuracy can be achieved when the entire tumor is within the sensitive region of diffuse light. Image reconstruction with a priori knowledge of the tumor volume and location can significantly improve the accuracy in recovery of tumor blood flow contrasts. In vivo imaging results from two breast carcinomas show higher average blood flow contrasts (5.9- and 10.9-fold) in the tumor regions compared to the surrounding tissues, which are comparable with previous findings using diffuse correlation spectroscopy. The ncDCT system has the potential to image blood flow distributions in soft and vulnerable tissues without distorting tissue hemodynamic

    Simultaneous measurement of deep tissue blood flow and oxygenation using noncontact diffuse correlation spectroscopy flow-oximeter

    Get PDF
    We report a novel noncontact diffuse correlation spectroscopy flow-oximeter for simultaneous quantification of relative changes in tissue blood flow (rBF) and oxygenation (Δ[oxygenation]). The noncontact probe was compared against a contact probe in tissue-like phantoms and forearm muscles (n = 10), and the dynamic trends in both rBF and Δ[oxygenation] were found to be highly correlated. However, the magnitudes of Δ[oxygenation] measured by the two probes were significantly different. Monte Carlo simulations and phantom experiments revealed that the arm curvature resulted in a significant underestimation (~-20%) for the noncontact measurements in Δ[oxygenation], but not in rBF. Other factors that may cause the residual discrepancies between the contact and noncontact measurements were discussed, and further comparisons with other established technologies are needed to identify/quantify these factors. Our research paves the way for noncontact and simultaneous monitoring of blood flow and oxygenation in soft and vulnerable tissues without distorting tissue hemodynamics

    Diethylene glycol poisoning and liver function following accidental diethylene glycol injection

    Get PDF
    The aim of the present study was to investigate the hepatotoxic effects of accidental intravenous diethylene glycol (DEG) poisoning in patients with liver disease. Clinical manifestations were recorded and liver function tests were carried out for 64 patients with liver disease who had been accidentally treated intravenously with DEG. Comparisons were made between the poisoned and non-poisoned groups. Of the 64 cases with preexisting liver disease, 15 cases (23.4 %) developed toxic presentations after exposure to DEG. All cases were men. Twelve of the 15 poisoned patients (80 %)died within seven days. The intravenous administration of DEG resulted in only mild liver function impairment. Gender (p = 0.039) and the severity of jaundice prior to DEG administration were risk factors related to the occurrence of toxin-induced renal failure (p < 0.006). The results suggest that DEG may worsen liver damage in patients with preexisting liver disease. However, our study demonstrated only mild, transient alterations in patients’ baseline liver functions. Severe liver damage secondary to DEG was only occasionally seen in patients with concomitant renal failure

    Exploring the heterogeneity of effects of corticosteroids on acute respiratory distress syndrome: a systematic review and meta-analysis

    Get PDF
    INTRODUCTION: The effectiveness of corticosteroid therapy on the mortality of acute respiratory distress syndrome (ARDS) remains under debate. We aimed to explore the grounds for the inconsistent results in previous studies and update the evidence. METHODS: We searched MEDLINE, Cochrane Central Register of Controlled Trials and Web of Science up to December 2013. Eligible studies included randomized clinical trials (RCTs) and cohort studies that reported mortality and that had corticosteroid nonusers for comparison. The effect of corticosteroids on ARDS mortality was assessed by relative risk (RR) and risk difference (RD) for ICU, hospital, and 60-day mortality using a random-effects model. RESULTS: Eight RCTs and 10 cohort studies were included for analysis. In RCTs, corticosteroids had a possible but statistically insignificant effect on ICU mortality (RD, −0.28; 95% confidence interval (CI), −0.53 to −0.03 and RR, 0.55; 95% CI, 0.24 to 1.25) but no effect on 60-day mortality (RD, −0.01; 95% CI, −0.12 to 0.10 and RR, 0.97; 95% CI, 0.75 to 1.26). In cohort studies, corticosteroids had no effect on ICU mortality (RR, 1.05; 95% CI, 0.74 to 1.49) but non-significantly increased 60-day mortality (RR, 1.30; 95% CI, 0.96 to 1.78). In the subgroup analysis by ARDS etiology, corticosteroids significantly increased mortality in influenza-related ARDS (three cohort studies, RR, 2.45, 95% CI, 1.40 to 4.27). CONCLUSIONS: The effects of corticosteroids on the mortality of ARDS differed by duration of outcome measures and etiologies. Corticosteroids did not improve longer-term outcomes and may cause harm in certain subgroups. Current data do not support routine use of corticosteroids in ARDS. More clinical trials are needed to specify the favorable and unfavorable subgroups for corticosteroid therapy

    Noncontact Diffuse Optical Assessment of Blood Flow Changes in Head and Neck Free Tissue Transfer Flaps

    Get PDF
    Knowledge of tissue blood flow (BF) changes after free tissue transfer may enable surgeons to predict the failure of flap thrombosis at an early stage. This study used our recently developed noncontact diffuse correlation spectroscopy to monitor dynamic BF changes in free flaps without getting in contact with the targeted tissue. Eight free flaps were elevated in patients with head and neck cancer; one of the flaps failed. Multiple BF measurements probing the transferred tissue were performed during and post the surgical operation. Postoperative BF values were normalized to the intraoperative baselines (assigning “1”) for the calculation of relative BF change (rBF). The rBF changes over the seven successful flaps were 1.89±0.15, 2.26±0.13, and 2.43±0.13 (mean±standard error), respectively, on postoperative days 2, 4, and 7. These postoperative values were significantly higher than the intraoperative baseline values (
    • 

    corecore